How to locate a DI-155/145/149 from UltimaSerial
There are three different ways to locate a DI-155, DI-145 and DI-149 when using
Ultimaserial controls.
Methods |
Application |
Let Ultimaserial find it for you:
To do so, assign
UltimaSerial will find the first DI-155, DI-145 or 149 on your PC and use it
|
Perfect if you use only one DI-155, DI-145 or 149 at a time and it maybe on
any USB port |
Specify the serial number and let UltimaSerial find
it for you.
To do so, assign
assuming 434334343 is the serial number of your DI-145/149
printed on the bottom of the case
UltimaSerial will find the DI-155, DI-145/149 with the matching serial
number on your PC and use it
|
Perfect if you have multiple DI-155, DI-145s and/or 149s, and they maybe
on any USB port and you need to start them based on their specific
serial number
|
Specify the virtual CommPort
DI-155, DI-145/149 is assigned by Windows
To do so, assign
assuming 3 is the virtual comm port of your device listed
under Window's Device Manager (see screen capture above)
UltimaSerial will find the DI-155, DI-145/149 attached to the specified
virtual comm port on your PC and use it
|
Perfect if you have multiple DI-155, DI-145s and/or 149s, and they maybe
on any USB port and you need to start them based on their USB port
connection. Please note that unless you overwrite Window's
assignment, each USB port will be associated with an unique COM
port number when connecting to DI-155, DI-145U/149U. You can run Window's Device Manager
to confirm it. |
Special Notes
DI-145's Compatibility with DI-194
DI-145 is 100% backward compatible with DI-194, but this declaration
is based on WinDaq application, not the protocol level. UltimaSerial
uses L and M commands to fine tune the sample
rate for DI-194, and these two commands are no longer available in
DI-145's protocol, thus programmer should not mix a DI-145 with a
DI-194, or the sample rate will be wrong.
Maximum sample rate of DI-145
480 s/s to match different versions of DI-194.
DI-145 yields 12 bit
result, but around10 bit resolution
How to locate a
DI-155/DI-145/DI-149
manually from Window's Device Manager
DI-155/145/149 is a USB-based virtual COM port device, meaning it will appears
under Ports (COM & LPT) configuration section of Window's Device
Manager (see screen capture below), taking up a COM port assigned by Windows. When you move
DI-155/145/149
to a different USB port, a different virtual COM port will be
assigned to it. You may change this assignment under Window's Device
Manager, but you should not make two different USB ports share the same
virtual COM port or conflict may occur.